Keithley 2601 Keithley SourceMeter, 3A DC, 40W, 1 Ch.
The Keithley 2601 SourceMeter lets you make precision DC, pulse, and low frequency AC source-measure tests faster, easier, and more economically than before. The Keithley 2601 offers two to four times the test speed of competitive products for I-V functional testing by combining:
- Product Introduction
Overview and Features
The Keithley 2601 SourceMeter lets you make precision DC, pulse, and low frequency AC source-measure tests faster, easier, and more economically than before. The Keithley 2601 offers two to four times the test speed of competitive products for I-V functional testing by combining:
● Keithley’s high speed, third-generation Source-Measure Unit (SMU) design
● An embedded Test Script Processor (TSP™)
● TSP-Link™, a fast triggering and inter-unit communication bus
The Keithley 2601 has a single 40W, 3A channel and is electrically isolated to ensure high measurement integrity and wiring flexibility. The Keithley 2601 packs many instruments into a small package, including:
● Aprecision power supply
● A true current source
● A 51/2-digit multimeter
● A voltage or current pulse generator with measurement
● A low frequency arbitrary waveform generator
● An electronic load
● A trigger controller
Features and Specifications of the Keithley 2601 include:
● TSP-Link allows connection of multiple 2600 series instruments in a master/slave config allowing unlimited scalability
● On-board Test Script Processor processes and runs complex sequences from the instrument - gives you up to 10X greater throughput
o allows creation of custom measurement functions for components such as varistors, diodes and BJTs/FETs, or algorithm based tests like I-V sweeps with power compliance, linearity and latch-up test sequences, and thermal response tests.
● Store up to 50,000 lines of TSP code and more than 200,000 readings in 16MB of nonvolatile memory.
● Measure I and V at >10,000 readings/s. Execute a full source-measure cycle in just 200µs
● Ensure repeatable timing and high throughput with the high speed auto-ranging function.
● GPIB, RS-232 and 14-bit digital I/O interface ports are standard
● Current measure range (per channel) 1pA to 3A
● Current source range (per channel) 5pA to 3A
● Basic current programming accuracy 0.03%
● Basic current measurement accuracy 0.02%
● Voltage measure range (per channel) 1µV to 40V
● Voltage source range (per channel) 5µV to 40V
● Basic voltage programming accuracy 0.02%
● Basic voltage measurement accuracy 0.015%
● Readings to memory 10,000/s
● Sweep source change and reading to memory 5,500/s
● Sweep source change and reading to GPIB 3,600/s
● Spot readings to GPIB 1,100/s
● Spot source change and reading to GPIB 880/s
● Pulse capability 200µs minimum source/measure pulse