DSOX3054A Agilent Digital Oscilloscope 500 MHz, 4 Ch.
The Keysight DSOX3054A is a four-channel model in the InfiniiVision 3000 X-Series. Engineered with breakthrough technology this upgradable oscilloscope provides superior performance and functionality. Its unique 5-instruments-in-one design delivers more scope for the same budget.
- Product Introduction
Overview and Features
The Keysight DSOX3054A is a four-channel model in the InfiniiVision 3000 X-Series. Engineered with breakthrough technology this upgradable oscilloscope provides superior performance and functionality. Its unique 5-instruments-in-one design delivers more scope for the same budget.
Features of the Agilent DSOX3054A include:
● One million waveforms per second update rate
● MegaZoom IV smart memory technology
● Large 8.5-inch WVGA display
● Optional segmented memory
● Industry's first 5-instruments-in-1:
o Oscilloscope
o Digital channels
o Built-in 20 MHz function/arbitrary waveform generator with modulation
o Integrated digital voltmeter
o Protocol analyzer
● Investment protection with Industry's only fully-upgradable oscilloscope, including bandwidth up to 1 GHz
● Industry's leading applications solution
Specifications of the Agilent DSOX3054A include:
● Bandwidth (-3 dB): 500 MHz
● Calculated rise time (10 - 90%): ≤ 700 ps
● Input channels: 4 analog channels
● Maximum sample rate:
o 4 GSa/s half channel
o 2 GSa/s all channel
● Maximum memory depth:
o Standard 2 Mpts
o Optional 4 Mpts
o Optional segment memory
● Display size and type: 8.5 WVGA display
● Waveform update rate: > 1 million waveforms per second
● Number of active probes supported: In general, one for 2-channel models
● Vertical system analog channels:
o Hardware bandwidth limits: Approximately 20 MHz (selectable)
o Input coupling: AC, DC
o Input impedance: Selectable:
● 1 MΩ ± 1% (14 pF)
● 50 Ω ± 1.5%
o Input sensitivity range: 1mV/div to 5 V/div (1 MΩ and 50 Ω)
o Vertical resolution: 8 bits (measurement resolution is 12 bits with averaging)
o Maximum input voltage:
● 300 Vrms, 400 Vpk
● Transient overvoltage 1.6 kVpk
● With N2862A, N2863A, N2890A 10:1 probe: 300 Vrms
● Frequency de-rating (assumes sine wave input): 400 Vpk until 40 kHz, then de-rates at 20 dB/dec until 6 Vpk
o DC vertical accuracy: ±[DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale]
o DC vertical gain accuracy: ± 2.0% full scale
o DC vertical offset accuracy: ± 0.1 div ± 2 mV ± 1% of offset setting
o Channel-to-channel isolation: > 100:1 from DC to maximum specified bandwidth of each model (measured with same V/div and coupling on channels)
o Offset range:
● ± 2 V (1 mV/div to 200 mV/div)
● ± 50 V (> 200 mV/div to 5 mV/div)
● Vertical system digital channels:
o Digital input channels: 16 digital (D0 to D15. pod 1:D7 ~ D0, Pod 2: D15 ~ D8)
o Thresholds: Threshold per pod
o Threshold selections: TTL (+1.4 V), 5V CMOS (+2.5 V), ECL (-1.3 V), user-defined (selectable by pod)
o User-defined threshold range: ± 8.0 V in 10 mV steps
o Maximum input voltage: ± 40 V peak CAT l; transient overvoltage 800 Vpk
o Threshold accuracy: ± (100 mV + 3% of threshold setting)
o Maximum input dynamic range: ± 10 V about threshold
o Minimum voltage swing: 5 mVpp
o Input impedance: 100 kΩ ± 2% at probe tip
o Input capacitance: ~8 pF
o Vertical resolution: 1 bit
● Horizontal system analog channels:
o Time base range: 1 Ns/div to 50 s/div
o Time base accuracy: 25 ppm ± 5 ppm per year (aging)
o Time base delay time range:
● Pre-trigger: Greater of 1 screen width or 250 μs
● Post-trigger: 1 s to 500 s
o Channel-to-channel deskew range: ± 100 ns
o Δ Time accuracy (using cursors): ± (time base acc. x reading) ± (0.0016 x screen width) ± 100 ps
o Modes: Main, zoom, roll, XY
o XY:
● On channels 1 and 2 only, Z Blanking on ext trigger input, 1.4 V threshold
● Bandwidth: Maximum bandwidth
● Phase error at 1 MHz: < 0.5 degree
● Horizontal system digital channels:
o Minimum detectable pulse width: 5 ns
o Channel-to-channel skew:
● 2 ns (typical)
● 3 ns (maximum)
● Aquisition system:
o Maximum analog channels sample rate:
● 4 GSa/s half channel interleaved
● 2 GSa/s all channel
o Maximum analog channels record length:
● 2 Mpts half channel interleaved, 1 Mpts all channel (standard)
● 4 Mpts half channel interleaved, 2 Mpts all channel (optional with DSOX3MEMUP (-040))
o Maximum duration of time captured at highest sampling rate (all analog channels): 500 us with 4M memory upgrade
o Maximum digital channels sample rate: 1 GSa/s
o Maximum digital channels record length:
● 1 Mpts (standard with digital channels only)
● 2 Mpts (optional with DSOX3MEMUP - with digital channels only)
o Modes:
● Normal: Default mode
● Peak detect: Capture glitches as narrow as 250 ps at all time base settings
● Averaging: Selectable from 2, 4, 8, 16, 64, ... to 65,536
● High resolution:
● Real time boxcar averaging reduces random noise and effectively increases vertical resolution
● 12 bits of resolution when ≥ 10 μs/div at 4 GSa/s
● or ≥ 20-μs/div at 2 GSa/s
● Segmented:
● Segmented memory optimizes available memory for data streams that have long dead times between activity
● Maximum segments = 1000
● Re-arm time = 1 μs (minimum time between trigger events)
● Trigger system:
o Trigger sources: Analog channel (1~4), digital channel (D0~D15), line, external, WaveGen (1 or mod) (FM/FSK)
o Trigger modes:
● Normal (triggered): requires trigger event for scope to trigger
● Auto : triggers automatically in absence of trigger event
● Single: triggers only once on a trigger event, press [Single] again for scope to find another trigger event, or press [Run] to trigger continuously in either Auto or Normal mode
● Force: front panel button that forces a trigger
o Trigger coupling:
● DC: DC coupled trigger
● AC: AC coupled trigger, cutoff frequency: < 10 Hz (internal);
● High frequency reject: cutoff frequency ~ 50 kHz
● Low frequency reject: cutoff frequncy ~ 50 kHz
● Noise reject:
● Selectable OFF or ON
● Decreases sensitivity 2x
o Trigger holdoff range: 40 ns to 10.00 s
o Trigger sensitivity:
● Internal: < 10 mV/div: greater of 1 div or 5 mV; ≥ 10 mV/div: 0.6 div
● External:
● 200 mVpp from DC to 100 MHz
● 350 mVpp 100 MHz to 200 MHz
o Trigger level range:
● Any channel: ± 6 div from center screen
● External: ± 8 V